PRODUCT CATALOG

Cardiac Rhythm Management | Connectivity and Remote Care | Connectivity

External Pulse Generator Single-Chamber

Model 3077

Product Highlights

  • Designed for safe and reliable temporary stimulation of the heart in cases of rhythm disturbances and conduction defects
  • An extensive single-chamber feature set, including mode choices, a wide base rate range, adjustable amplitude and sensitivity parameters, and two modes of high-rate pacing
  • Up to 12 volts of output available per channel make the Model 3077 temporary pacemaker one of the highest-output devices of its kind available
  • Designed for ease of use:

– Standard 9 volt lithium or alkaline batteries are used, and the device features both visual and audible battery life indicators

– Large, simple dial

– Small size and lightweight design

  • Runaway protection limits the device to a maximum rate of 200 ppm in the unlikely event of circuit malfunction
External Pulse Generator Model 3077


Ordering Information

Contents: External pulse generator

 

Reorder Number Dimensions (H x W x T, cm) Weight (g) Battery
3077 6 x 11.5 x 2.2 185 (includes battery) Standard 9 V, alkaline or lithium

Brief Summary: Prior to using these devices, please review the Instructions for Use for a complete listing of indications, contraindications, warnings, precautions, potential adverse events and directions for use. Devices depicted may not be available in all countries. Check with your St. Jude Medical representative for product availability in your country.

Indications for Use: When combined with a stimulation lead system, the Model 3077 SSI temporary pulsegenerator can be used whenever temporary atrial or ventricular stimulation is indicated. The device can beemployed for therapeutic as well as diagnostic purposes or be used prophylactically.

Some specific indications for temporary stimulation are:

- Complete (third-degree) or intermittent heart block

- Symptomatic sinus bradycardia

- Atrial or ventricular ectopic arrhythmia

- Sick sinus syndrome (SSS)

- Acute myocardial infarction induced heart block

- Stimulation during a ventricular asystole

- Usage during the replacement of an implantable pacemaker

- Stimulation and monitoring before the implantation of a cardiac pacemaker

- Stimulation and monitoring following heart surgery

Contraindications: The Model 3077 SSI temporary pulse generator is contraindicated:

- In the treatment of ventricular tachycardia- When overall physiological condition of the patient limits the selection of the stimulation mode and thestimulation parameters.